transfers accurately proportional levels of current to multiple circuits.


Showing results: 256 - 270 of 340 items found.

  • Primary Test Equipment

    LET-400-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

  • 20Hz Generator

    Signals & Systems India Private Limited

    In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.

  • HeavyPower & EasyPower

    Transformer Series - Smiths Interconnect

    Transformer Series offers a customer configurable architecture, with just a few piece parts to create several types of connectors as a platform solution. No special tools are needed except crimping tools, resulting in a reduced stock and kitting/logistic management. The series offers a high reliability due to the Tortac® contact and provides up to 500 mating cycles and high current rating up to 300A/500A.

  • Leakage Current Monitor

    LCM500 - Doble Engineering

    The Doble LCM500 Leakage Current Monitor can measure condition while a surge arrester is still in service, measuring the quality of the metal oxide blocks and helping manage the risk of failure.A surge arrester may be inexpensive, but it has an important role in protecting your transformers.With the LCM500, it takes less than 15 minutes to establish that your surge arresters are healthy and the transformer is still protected.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Loading Transformer

    CL-6 - The Eastern Specialty Company

    This readily portable Knopp Loading Transformer weighs only 60 pounds and measures 12″ long, 9″ wide, and 10″ high. Its sturdy enclosure provides protection and adequate ventilation. Two convenient carrying handles are provided. The insulating terminal panel is rigidly secured to the transformer frame, and heavy-current, bus-bar-type terminals are securely bolted to the panel. The two outpout terminals each have two connection surfaces, one on a vertical plane and one on a horizontal plane, for maximum convenience in connecting the heavy current leads and in changing, when necessary, the series-parallel links. The links and the output connections cannot interfere with each other. All terminals and connection links are plated

  • CT/VT Test System

    Eltel Industries

    Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.

  • 10A DIGITAL MICRO-OHMMETER

    MPK-2000e - MEGABRAS srl

    The MPK-2000e digital very low resistance ohmmeter is a portable, microprocessor controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10A. It uses the Kelvin-type, four-terminals measurement principle, thus eliminating errors caused by lead and contact resistances.

  • Chroma Milliohm Meters

    Chroma Systems Solutions, Inc.

    The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.

  • Wide Angle Scale Instrument

    LS-96 - Standard Electric Works Co., Ltd

    ● For ranges higher than 20A DC, use external shunt with a 50mV DC Ammeter.● For ranges higher than 300V DC, use external Volt Divider with a 1mA Voltmeter.● For ranges higher than 5A AC, use external Current Transformer with a 5A AC Ammeter. ● For ranges higher than 600V AC, use external Potential Transformer with a 150V AC Voltmeter.● Full Scale Deflection : 250° ● Accuracy : Class 1.5● Composition : Glass window, ABS resin frame and case, PC glass fiber base mounting fittings included.● Color : Black base and frame, white scale plate and meter body.● Pointer : Stick shape in black color.

  • 2KVA Scaler Transformer

    T-1005 - Compact Power Company

    The Titan Series T-1005 Scaler Transformer is used to conveniently scale the standard OV to 130V/260V full scale AC Power Source/Frequency Converter output to 76 different full scale voltages and currents. It is also used to join and scale the power from multiple Titan series AC Power Sources/Frequency Converters into a single output. It has a conservative continuous power rating of 2KVA and excellent voltage regulation.

  • MOTORIZED TRANSFORMER/RECTIFIER ASSEMBLY, 0-250 VDC, 200 A OUTPUT

    18534PS1 - Carl E. Holmes Company

    Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure

  • DC Power Supplies

    EZ Digital, Inc.

    Power Supplies deliver electric power to a device or circuit (Electrical Load), usually by stepping down a higher voltage. DC Power Supplies step down the voltage and convert it to DC. For example, 220 VAC to 12 VDC. Every power supply has an input or supply power and converts it by various methods to meet the demand from the electrical load. Power supplies are said to be Regulated by controlling the output voltage or current to a constant value, even if the load demand current or the supply power varies. At the heart of any power supply is a Transformer, which converts the supply power to the output power to the load.

  • DC Power Supply

    ◎PW-4063R - PINTEK Electronics

    *Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.

  • DC High-Voltage Test Device

    PGK 80 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal